BEA’s MICROCELL is designed to provide safety for automatic sliding door thresholds and swing door guiderails.
The MICROCELL is a compact, self-contained system of beams that fits easily into ½ inch pre-drilled holes and requires a single wire connection on each side.
The MICROCELL is available either in a single or double beam version with an optional 32 foot cable.
BEA’s MICROCELL is designed to provide safety for automatic sliding door thresholds and swing door guide rails.
The MICROCELL is a compact, self-contained system of beams that fits easily into ½ inch-pre-drilled holes and requires a single wire connection on each side.
The MICROCELL is available either in a single or double-beam version with an optional 32-foot cable.
TECHNOLOGY:
Active Infrared
DETECTION MODE:
Presence (Beam Interruption)
MIN. MOUNTING HEIGHT:
12” from floor
MIN. DISTANCE BETWEEN BEAMS:
12” (crossed beams)
MIN. RANGE OF DETECTION:
3’
MAX. RANGE OF DETECTION:
15’
ALIGNMENT TOLERANCE:
8°
RESPONSE TIME:
≤ 40 ms
HOLD TIME:
300 ms
SUPPLY VOLTAGE:
12 – 24 VAC; ±10%
12 – 24 VDC; –5% / 30%
CURRENT CONSUMPTION:
< 100 mA
OUTPUT CONTACT RATING - 1 Relay (NC / NO contacts)
MAX. CONTACT VOLTAGE - 50 VAC / VDC
MAX. CONTACT CURRENT - 1 A
MAX. SWITCHING POWER - 30 W (DC) / 60 VA (AC)
OPERATING TEMPERATURE:
-30 – 131 °F
IMMUNITY:
SUNLIGHT - 75,000 lux
INCANDESCENT LAMP - 25,000 lux @ 8° angle
ELECTROMAGNETIC COMPATIBILITY - According to 89 / 336 EEC
DIMENSIONS:
HEAD BODY - < 15⁄32” (L embed) × 15⁄32” (ø)
HEAD HARNESS - 5⁄8” (ø)
CONTROL BOARD - 3 1⁄33” (W) × 1 2⁄25” (H) × 2 1⁄33” (D)
CABLE LENGTH:
18’ (standard)
32’ (optional)
MATERIAL:
ABS
DEGREE OF PROTECTION:
NEMA 4 / IP65 (beam heads)