BEA 10MATRIXD1224 Dual Loop Detector, 12-24VAC/VDC

$116.35

BEA’s MATRIX FAMILY of induction loop detectors is designed for vehicle detection application in industrial environments.

These UL 508 listed loop detectors offer a wide range of features including automatic boost sensitivity (ABS), pulse on entry and pulse on exit. The MATRIX 3 provides learn on power up, as well as an independent dual loop detection setting.

The MATRIX FAMILY includes single and dual loop detectors with operating voltages of 110 – 120 VAC or 12 – 24 VAC / VDC, depending on model.

Availability: In stock

BEA’s MATRIX FAMILY of induction loop detectors is designed for vehicle detection application in industrial environments.

These UL 508 listed loop detectors offer a wide range of features including automatic boost sensitivity (ABS), pulse on entry and pulse on exit. The MATRIX 3 provides learn on power up, as well as an independent dual loop detection setting.

The MATRIX FAMILY includes single and dual loop detectors with operating voltages of 110 – 120 VAC or 12 – 24 VAC / VDC, depending on model.

 

TUNING:
Automatic

CONNECTOR:
11-pin male (86CP11)

PRESENCE TIME:
1 min – infinity

PULSE TIME OUTPUT:
100 ms or 500 ms

LED INDICATORS:
GREEN - Power
RED - Loop Status 1 / Loop Status 2

FREQUENCY RANGE:
20 kHz – 130 kHz

FREQUENCY STEPS:
SINGLE LOOP - 4
DOUBLE LOOP - 2 (for each loop)


SENSITIVITY (ΔL/L):
0.005 – 0.5%

REACTION TIME:
SINGLE LOOP - 25 ms
DOUBLE LOOP - 50 ms (each channel)

SETUP TIME AFTER CONFIGURATION:
2 s max by channel

POWER SUPPLY - 12 – 24 AC / DC ±10%
(DEPENDING ON MODEL) - 115 VAC ±10%

POWER FREQUENCY:
48 – 62 Hz

POWER CONSUMPTION:
< 2.5 W

TEMPERATURE RANGE:
-22 – 158 °F (-30 – 70 °C)

PROTECTIONS:
Loop Insulation Transformer
Zener Diodes
Gas Discharge Clamping

INDUCTANCE RANGE:
20 – 1000 μH

CONNECTION:
86CP11 (Standard 11-Pin Round)

RELAY OUTPUTS: 2 (free potential change-over contact)
MAX. CONTACT VOLTAGE - 230 VAC
MAX. CONTACT CURRENT - 5 A (resistive)

SETUP TIME AT POWER ON:
MATRIXD/S - 8 s max by channel
MATRIXIIS - 8 s max by channel
MATRIX-3S - 1.6 s max by channel
MATRIX-3D - 2.2 s max by channel


NORM CONFORMITY:
R&TTE: 1999 / 5 / EC
EMC: 89 / 336 / EEC
EMC: 89 / 336 / EE
EMC: 2004 / 108 / EC
FCC: 47 CFR 15
IC: RSS-210 ISSUE 5
UL Listed equipment for UL 508

DEGREE OF PROTECTION:
IP40

WEIGHT:
7 oz

DIMENSIONS:
1 ½” (W) × 3” (H) × 3” (D)